U.V STERILIZER

  • U.V STERILIZER

    Model                                  Violet Alimentation
    Alimentation                     230V50Hz
    Absorbed Power              18 W
    Fuse                                   2 x 1A
    Dimention Outer            49 x 27 x 20 cm (LxDxH)

    Principle of operation:
    Cold Sterilization through irradiation with short wave ultraviolet rays

    The vapor of mercury at to low pressure contained in the lamp, submitted to electric discharge, give out a short wave radiations that will be distribute for the 90% around the frequency of 253,7 nm, and in tall frequencies the lamp give out a visible light of bluish color. It is just around the 253,7 run that is developed the maximum germicidal power

    A low radiation is gived ot on the frequency of 185 run and it provokes a small issue of ozone with deodorant effect

    Germicidal action:
    The ultraviolet radiations are lethal for the microorganisms.The quantity of radiation necessary to destroy a microorganism depends from the type of the microrganism and from the environmental conditions
    The lethal dose of radiation UV for a determined microorganism depends therefore from the intensity of the source, from the exposure time and from other factors like temperature, damp and the reflection formalities of the rays
    Our apparatus has been planned and built in way to maximize the effect of the radiations and to assure an optimal result in varied uses
    It is ideal for a suitable maintenance of the tools after the sterilization

Description

UV STERILIZER

Model                                  Violet Alimentation
Alimentation                     230V50Hz
Absorbed Power              18 W
Fuse                                   2 x 1A
Dimention Outer            49 x 27 x 20 cm (LxDxH)

Principle of operation:
uv sterilizer Cold Sterilization through irradiation with short wave ultraviolet rays

The vapor of mercury at to low pressure contained in the lamp, submitted to electric discharge, give out a short wave radiations that will be distribute for the 90% around the frequency of 253,7 nm, and in tall frequencies the lamp give out a visible light of bluish color. It is just around the 253,7 run that is developed the maximum germicidal power

A low radiation is gived ot on the frequency of 185 run and it provokes a small issue of ozone with deodorant effect

Germicidal action:
The ultraviolet radiations are lethal for the microorganisms. The quantity of radiation necessary to destroy a microorganism depends from the type of the microorganism and from the environmental conditions
The lethal dose of radiation UV for a determined microorganism depends therefore from the intensity of the source, from the exposure time and from other factors like temperature, damp and the reflection formalities of the rays
Our apparatus has been planned and built in way to maximize the effect of the radiations and to assure an optimal result in varied uses
It is ideal for a suitable maintenance of the tools after the sterilization